Hệ thống đo chất lượng không
khí
Model: IQM 60
Hãng sản xuất: AEROQUAL -
New Zealand
Tham khảo tại: http://www.aeroqual.com
-
The IQM 60 Indoor Air Quality
Monitor enables simultaneous monitoring of common indoor air quality parameters
with a single instrument.
-
IQM 60 Indoor Air Quality
MonitorAeroqual's proprietary Analytic GSS Technology is integrated with
photo-ionization detector (PID) and nondispersive infra-red (NDIR) sensors to
achieve cost effective and precise measurement of gases including carbon
dioxide (CO2), carbon monoxide (CO), volatile organic compounds (VOC), nitrogen
dioxide (NO2) and ozone (O3). Other sensors are integrated for measuring
temperature, humidity and particulate matter.
-
Air quality data for each
parameter is logged to a removable SD card or to a PC in real-time and can be
exported for generating reports. Applications include IAQ and HVAC analysis,
IAQ complaint investigation, and Sick Building Syndrome (SBS) assessment. The
IQM 60 offers the complete package for performing in-depth analysis of indoor
air quality.
Features:
-
Multiple Gas Measurements
-
Temperature and Relative Humidity
-
GSS, PID and NDIR Sensor
Technology
-
Factory Certified – NIST
Traceable
-
Temperature and Humidity Sensors
-
Particulate Measurement Options:
§ Particle
Counter: 2-channel
§ Particulate
Profiler: 8-channel
§ Particle
Monitor: TSP, PM1, PM2.5, PM10
-
Active-air Sampling System
-
Multi-point Factory Sensor
Calibration
-
Zero and Span Calibration
User-facility
-
Real-time Data Sampling
-
Removable Data Storage
-
PC Data-logging Software
-
Wireless Communication Options
-
Compact and Portable
-
Low Maintenance
Application:
-
IAQ Complaint Investigation and
Analysis
-
HVAC System Performance
Monitoring
-
Sick Building Syndrome (SBS)
Surveys
-
Health and Comfort Assessment
-
Odour Investigation and
Remediation
-
Testing the Efficiency of Air
Purifiers
-
Clean Room Monitoring and
Verification
-
Filtration Testing
-
Residential and Commercial
Buildings
-
Airport Lounges and Shopping
Malls
-
Schools and Kindergartens
-
Hospitals and Elderly Care
Facilities
-
Epidemiological Studies
-
Re-entrainment Studies
Specifications:
|
Gas
Modules
|
Calibrated
range
|
Minimum
detection limit
|
Accuracy
of Factory Calibrated
|
Precision
|
Resolution
|
|
Carbon Dioxide CO2 (NDIR)
|
0
– 2000 ppm
|
6
ppm
|
<40
ppm + 3% of reading
|
10
ppm
|
1
ppm
|
|
Carbon Dioxide CO2 (NDIR)
|
0
– 5000 ppm
|
6
ppm
|
<150
ppm + 6% of reading
|
10
ppm
|
1
ppm
|
|
Carbon Monoxide CO (GSE)
|
0
– 100 ppm
|
0.2
ppm
|
<±2
ppm 0-20 ppm; <±10% 20-100 ppm
|
0.2
ppm
|
0.1
ppm
|
|
Ozone O3 (GSS)
|
0
– 0.15 ppm
|
0.001
ppm
|
<±0.005
ppm
|
0.002
ppm
|
0.001
ppm
|
|
Ozone O3 (GSS)
|
0
– 0.5 ppm
|
0.001
ppm
|
<±0.008
0-0.1 ppm; <±10% 0.1-0.5 ppm
|
0.005
ppm
|
0.001
ppm
|
|
Nitrogen Dioxide NO2 (GSS)
|
0
– 0.2 ppm
|
0.001
ppm
|
<±0.010
0-0.1 ppm; <±10% 0.1-0.2 ppm
|
0.005
ppm
|
0.001
ppm
|
|
Volatile Organic Compounds
(PID)
(1)
|
0
– 20ppm
|
0.01
ppm
|
<±10%
|
0.02
ppm
|
0.01
ppm
|
|
Non-methane Hydrocarbon (GSS)
(1)
|
0
– 25ppm
|
0.1
ppm
|
<±10%
|
0.2
ppm
|
0.1
ppm
|
|
Volatile Organic Compounds
(GSS)
(1)
|
0
– 25ppm
|
0.1
ppm
|
<±10%
|
0.2
ppm
|
0.1
ppm
|
|
(1)
Calibrated to isobutylene (non-specific sensor)
|
|||||
|
Temp. & Humidity Sensor
|
Range Temp.
-20°C to +100°C
|
Range RH
0-100% RH
|
Accuracy Temp. | RH @ 25°C
±0.3°C | ±2% RH
|
Temp Res.
0.01°C
|
RH Res.
0.1% RH
|
|
Particulate Profiler
2-channels : >0.3 µm &
>2.5 µm
|
Range
0-100000
PPL
|
Particle
Sizes
>0.3
& >2.5 µm
|
Accuracy
±10%
to calibration aerosol
|
Flow
rate
1.0
LPM
|
Resolution
1
PPL
|
|
Particulate Profiler
8-channels : 0.3 to 10 µm
|
Range
0-100000
PPL
|
Particle
Sizes
0.3-10
µm (8)
|
Accuracy
±10%
to calibration aerosol
|
Flow
rate
1.0
LPM
|
Resolution
1
PPL
|
|
Particle Monitor
Inlet options : PM1 PM2.5 PM10
TSP
|
Range
0-2000
µg/m
|
Sensitivity
1
µg/m3
|
Accuracy
8%
of NIOSH 0600
|
Precision
3
µg/m3
|
Resolution
1
µg/m3
|
|
Controller Module
|
Communication
RS
232
|
Data
Storage
2
GB SD card
|
Data
Sampling Rate
2
to 255 minutes (programmable)
|
Display
VFD
4 x 20
|
PC
Software
Included
|
|
Gas Treatment Module
|
Sampling
Pump
BLDC
|
Zero
Scrubber
Built-in
|
Replaceable
Zero Scrubber Media Cartridges Chemisorbant, activated carbon & Hopcalite
|
||
- Environmental
Operating Range: 0 to 50°C; 10 to 90% RH (non-condensing)
- Communication
Interface: RS 232 (DB9 port)/ Cable & USB adaptor supplied
- Power
Supply (standard): Switch mode power supply 12V DC/ Input 90-260V AC; 47-63Hz
- Remote
Communication (optional): GSM/GPRS modem; Ethernet; Wireless
- Portable
Power Station (optional): Li-ion battery station & charger 222WH or other
capacity
- Dimensions PM models : 378 x 236 x 132 (mm)/ Non PM
models : 278 x 236 x 132 (mm)
- Enclosure
Material: Aluminium & powder-coated steel
- Instrument
Weight: Net 4-9 Kg (subject to
configuration)
Instrument
Carry Case: Impact & water resistant; 515 x 430 x 200 (mm)