Bộ chuyển tín hiệu đa thông số
Model:
OPTISENS MAC 100
Hãng sản xuất: Krohne – Đức
Product Features:
Highlights:
- KROHNE
General Device Concept (GDC)
- Standardised
operating concept from flow and level extended to analytical parameters
- Up
to 2 sensor inputs + temperature input
- 3
current outputs
- Large
graphic display
- Robust
aluminium housing (IP66)
- Build-in
temperature and pH compensation
- Calibration
logbook
- HART
(in preparation)
Industries:
- Water
/ Waste water
- Power
industry
- Process
industry
- Food
and Beverages
Specifications:
Measuring
system:
- Measuring
principle: Depends on the used sensor(s)
- Application
range: Continuous measurement of parameters in liquid analysis applications.
- Measuring
range: Depends on the used sensor(s)
Design:
- Construction
A typical measuring system consists of:
§ MAC
100 multiparameter signal converter
§ 1
(or up to 2) sensors of the OPTISENS series
§ Sensor
cable
§ MAA
mounting assemblies
- Option
The device is available as a one channel (one signal input) or a two channel
version (two signal inputs). You can connect one sensor to the one channel
version and up to two sensors to the two channel version.
- Sensors
For further information refer to the
manual of the relevant sensor.
- Also
note the table with the sensor input combinations on page 7.
Display
and User interface:
- Graphic
display: LC display, backlit white 128 x 64 pixels
Note:
ambient temperatures below -25°C / -13°F" may affect the readability of
the display!
- Operating
elements: 4 push buttons for operator control of the signal converter without
opening the housing.
- Operating
menu:
§ The
operation menu consists of the measuring mode and the menu mode:
§ Measuring
mode: 4 pages (first and second measuring page with measuring results, status
message and trend diagram).
§ Menu
mode: variety of main and submenus that allow to customise the device according
to the demands of the measuring point.
- Operating
and display languages: English, German,
(others on request)
- Units:
Metric, British and US units selectable as required from lists
Measuring
accuracy:
- Reference
conditions:
§ Temperature:
20°C / 68°F
§ Pressure:
1 bar / 14.5 psi
- Maximum
measuring error: For further information refer to the manual of the relevant sensor.
- Repeatability:
For further information refer to the
manual of the relevant sensor.
- Resolution:
Temperature: 0.1°C / 0.1°F". For
further information refer to the manual
of the relevant sensor.
- Long-term
stability: 24 hours: tested within accuracy definition
- Temperature
drift: Tested within accuracy definition
- Cable
length variation: Tested within accuracy definition
Operating
conditions:
Temperature:
- Ambient:
-15...+55°C / +5...131°F
Note:
the manufacturer strongly recommends to protect the signal converter from
external heat sources such as direct sunlight as higher temperatures reduce the
life cycle of all electronic components.
- Storage:
-40...+70°C / -40...+158°F
Other
conditions:
- Humidity
(ambient): Max. 90% at 40°C / 104°F
- Pressure:
For information about the process pressure of the used sensor(s) refer to the
relevant sensor documentation!
- Protection
category acc. to IEC 529 / EN 60529: IP66/67 (acc. to NEMA 4/4X)
Installation
conditions:
- Installation:
Only wall mounting is possible, always assure a vertical mounting orientation!
- Dimensions
and weights: For detailed information see chapter "Dimensions and
weights".
Materials:
- Signal
converter: housing Die-cast aluminium (polyurethane coated)
- Measuring
sensor: For housing materials, process connections, liners, grounding
electrodes and gaskets, see the technical documentation for the measuring
sensor.
Electrical
connections:
- General:
Electrical connection is carried out in conformity with the VDE 0100 directive "Regulations
for electrical power installations with line voltages up to 1000 V" or
equivalent national regulations.
- Voltage:
100…230 VAC (-15% / +10%), 50/60 Hz; 240 VAC + 5% is included in the tolerance range.
- Power
consumption: 4.2 W, 10 VA at 230 VAC
- Fuse:
0.8 AT/250V (high breaking capacity ), 5 x 20 mm / 0.2 x 0.8"
- Line
frequencies: 50/60 Hz
- Power
rating: 22 VA (maximum)
- Inrush
current IN, eff = 97 mA, t15 = 1.5
ms, tPeak = 200 µs, Ipeak = 22.6 A
- Cable
entries:
§ 1 channel:
4 x M20
§ 2
channels (separate temperature sensor): 3 x M20, double PG two times 5 mm /
0.20" screwed connection for sensor cables
§ 2
channels (integrated temperature sensor): 3 x M20, double PG two times 8 mm /
0.31" screwed connection for sensor cables
Inputs
and outputs:
- General:
All in- and outputs are electrically
isolated from each other and from all other circuits. All operating data and
output values can be adjusted.
- Description
of used abbreviations: Uext = external voltage;
RL= load + resistance; Uo = terminal voltage; Inom = nominal current
Inputs:
- Sensor
inputs: Up to 2, depending on the version. For further information refer to
the manual of the relevant sensor.
- Control
input:
§ Passive,
not polarity sensitive, Uext, max ≤ 32 VDC, Inom = 6.5 mA with
Uext= 24 VDC, Inom = 8.2 mA
with Uext= 32 VDC
§ Switching
point for identifying "contact open or closed": contact open
("off") at U0 ≤2.5 V with Inom = 0.4 mA, contact closed
("on") at U0 ≥ 8 V with Inom = 2.8 mA
Outputs:
Current
outputs:
- Three
isolated outputs (4...20 mA), all galvanic isolated, errors signals 3.25 mA and
- 22
mA, active mode
- Output
data: depending on sensor
- Operating
data: Uint, nom = 15 VDC, I = 0(4)...22 mA, Imax ≤ 22 mA, RL≤ 550 Ω
Relay
outputs:
- Three
electro-mechanical relays that can work as alarm relays or limit switches
- Possible
conditions: NO (normally open) or NC (normally closed)
- Contact
ratings:
§ Relays
for low voltages: U ≤ 30 VDC, I ≤ 1 A, resistive load (PELV / SELV) or U ≤ 50
VAC, I ≤ 4 A, resistive load (PELV / SELV)
§ Relays
for high voltages: U = 100...230 VAC, I ≤ 4 A, max. 1000 VA resistive load
HART: In
preparation
Approvals
and certifications:
- CE: This
device fulfils the statutory requirements of the EC directives. The
- manufacturer
certifies successful testing of the product by applying the CE mark.
- Shock
resistance: IEC 68-2-3
- Electromagnetic
compatibility: 2004/108/EC in conjunction with EN 61326-1 (A1, A2)
- Low
Voltage Directive: Safety requirements for electrical equipment for
measurement, control, and laboratory use in accordance with EN 61010-1:2001.
Sensor
input combinations:
|
Sensor type
|
Measured
parameter
|
Measuring
principle
|
Signal converter
|
|
|
Input A
|
Input B
|
|||
|
PAS 1000 pH
|
pH value
|
Potentiometric
|
X
|
X
|
|
PAS 1000 ORP
|
ORP value
|
Potentiometric
|
X
|
X
|
|
AAS 1000 Cl2
|
Free chlorine
|
Amperometric
|
X
|
|
|
AAS 1000 ClO2
(1)
|
Chlorine dioxide
|
Amperometric
|
X
|
|
|
AAS 1000 H2O2
(1)
|
Hydrogen peroxide
|
Amperometric
|
X
|
|
|
AAS 1000 O3
(1)
|
Ozone
|
Amperometric
|
X
|
|
|
AAS 1000 DO
(1)
|
Dissolved oxygen
|
Amperometric
|
X
|
X
|
|
CAS 1000
(1)
|
Conductivity /
specific resistance
|
Conductive (2-
pole)
|
X
|
X
|
|
IAS 1000
(1)
|
Conductivity
|
Inductive
|
X
|
X
|
|
(1) In preparation
|
||||